INTRODUCTION:
F#1 Airbrush is the simplest in design with the least
number of parts, supplying independent control of air and
color. Ideal for use by students and hobbyists, also for touch up and decorating.
OPERATING INSTRUCTIONS
Pressures:
• 10 lbs. for stipple and granulated effects.
• 20 Ibs. for light consistency water colors, inks & dyes.
• 30 Ibs. for medium fluids, reduced lacquers,
varnishes, paints or ceramic glaze. F#1 Airbrush will
not handle heavy fluids.
1. Attach hose to air supply and allow to blow a few
seconds at full pressure. Shut off before attaching to
Airbrush. This procedure will remove dirt from airline
and hose.
2. Attach AC-20 (1/8”-1/4”-40) Coupling to the Airbrush.
3. Attach Color Cup or Bottle to FN-1 Needle by exerting
a firm twisting motion to fit taper tube securely into
tapered Needle inlet. To remove Color Cup from FN-1
Needle, exert a backwards twisting and pulling motion.
4. Fill Color Cup or Bottle 1/2 to 3/4 full. Use eyedropper
or brush for adding small amounts of color to cup. When using Color Bottle, vent hole must be kept open.
5. To Spray: Hold Airbrush like a pencil, comfortably
between thumb and forefinger using middle finger as a
guide and support.
6. Like writing, hold forefinger easily on H-155 Finger
Button-press to open air valve.
7. Regulate volume of color and size of spray by rotating
FT-1 Tip clockwise to increase, and counterclockwise
to decrease, flow of color.
8. Stipple adjustment: For a very coarse stipple, loosen
and slide back FN-1 Needle. Increase the volume of
fluid until a free flow of color is achieved. Regulate air
pressure and fluid feed for a variety of stipple effects.
CARE AND CLEANING:
1. Pour any remaining color back into its original
container.
2. Wipe Color Cup or Bottle clean, using a cloth
moistened with proper solvent.
3. Hold airbrush at a downward angle and put a few drops
of solvent through the F-1 Color Adjusting Part
Assembly. To flush out the remaining color in the F-1
Color Adjusting Part Assembly, apply pressure to the
H-155 Finger Button.
4. Apply a tiny dab of petroleum jelly to the F-1 Color
Adjusting Part Assembly and HC-1 Aircap threads every two or three months to prevent color build up and consequent freezing of the Color Adjusting Part Assembly and Aircap.
HOW TO OPEN CLOGGED FLUID PASSAGES:
1. Agitate color in Bottle Assembly by placing finger
momentarily over HC-1 Aircap while air is passing through the Airbrush. (This will blow color back into bottle thus opening clogged fluid passages.) Do not do this with a cup as color may blow out.
2. Should F-1 Color Adjusting Part Assembly become
clogged, loosen H-153 Set Screw, unscrew FT-1 Tip
from FN-1 Needle, gently pull back through ball shaped
support and remove Tip.
3. Clean Parts carefully, using nothing harder than a
wooden toothpick.
4. To reassemble, reverse this procedure, making sure
the shoulder of the needle seats up against ball shaped
support.
5. If the needle and tip are completely clogged, soak in a
closed bottle of proper solvent until clean.

Adhesives
Airbrushes
Artboxes
Books
Brushes
Canvas
Cardboard
Children
Colors
Crafts
Drafting
Furniture
Picture Frames
Graphic Arts
Knives & Cutters
Pads
Paint By Number
Palettes
Paper
Pens
Pencils
Portfolios
Printmaking
Sculpture
Browse by Brand
Overstock
About Us
Employment Opportunities
ViewCart